CVE-2012-4356

UnknownEPSS 27.49%

Last modified

CVE-2012-4356 is a vulnerability of currently unknown severity. Multiple directory traversal vulnerabilities in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allow remote attackers to read arbitrary files via port-46824 TCP packets specifying a file-open operation with opcode 0x78 and a .. (dot dot) in a pathname, followed by a file-read operation with opcode (1) 0x96, (2) 0x97, or (3) 0x98.. EPSS estimates a 27.49% chance of exploitation in the next 30 days.

Description

Multiple directory traversal vulnerabilities in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allow remote attackers to read arbitrary files via port-46824 TCP packets specifying a file-open operation with opcode 0x78 and a .. (dot dot) in a pathname, followed by a file-read operation with opcode (1) 0x96, (2) 0x97, or (3) 0x98.

Metrics

EPSS Probability
27.49%

97.8th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
SielcosistemiWinlog Pro<= 2.07.16
SielcosistemiWinlog Pro2.06.00
SielcosistemiWinlog Pro2.06.03
SielcosistemiWinlog Pro2.06.04
SielcosistemiWinlog Pro2.06.06
SielcosistemiWinlog Pro2.06.09
SielcosistemiWinlog Pro2.06.10
SielcosistemiWinlog Pro2.06.12
SielcosistemiWinlog Pro2.06.13
SielcosistemiWinlog Pro2.06.14
SielcosistemiWinlog Pro2.06.18
SielcosistemiWinlog Pro2.06.21
SielcosistemiWinlog Pro2.06.24
SielcosistemiWinlog Pro2.06.25
SielcosistemiWinlog Pro2.06.28
SielcosistemiWinlog Pro2.06.40
SielcosistemiWinlog Pro2.06.46
SielcosistemiWinlog Pro2.06.50
SielcosistemiWinlog Pro2.06.60
SielcosistemiWinlog Pro2.06.73
SielcosistemiWinlog Pro2.06.86
SielcosistemiWinlog Pro2.07.00
SielcosistemiWinlog Pro2.07.01
SielcosistemiWinlog Pro2.07.08
SielcosistemiWinlog Pro2.07.09
SielcosistemiWinlog Pro2.07.11
SielcosistemiWinlog Pro2.07.14
SielcosistemiWinlog Lite<= 2.07.16
SielcosistemiWinlog Lite2.06.00
SielcosistemiWinlog Lite2.06.03
SielcosistemiWinlog Lite2.06.04
SielcosistemiWinlog Lite2.06.06
SielcosistemiWinlog Lite2.06.09
SielcosistemiWinlog Lite2.06.10
SielcosistemiWinlog Lite2.06.12
SielcosistemiWinlog Lite2.06.13
SielcosistemiWinlog Lite2.06.14
SielcosistemiWinlog Lite2.06.18
SielcosistemiWinlog Lite2.06.21
SielcosistemiWinlog Lite2.06.24
SielcosistemiWinlog Lite2.06.25
SielcosistemiWinlog Lite2.06.28
SielcosistemiWinlog Lite2.06.40
SielcosistemiWinlog Lite2.06.46
SielcosistemiWinlog Lite2.06.50
SielcosistemiWinlog Lite2.06.60
SielcosistemiWinlog Lite2.06.73
SielcosistemiWinlog Lite2.06.86
SielcosistemiWinlog Lite2.07.00
SielcosistemiWinlog Lite2.07.01

Showing 50 of 54 affected configurations. See NVD for the full list.

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2012-4356?
Multiple directory traversal vulnerabilities in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allow remote attackers to read arbitrary files via port-46824 TCP packets specifying a file-open operation with opcode 0x78 and a .. (dot dot) in a pathname, followed by a file-read operation with opcode (1) 0x96, (2) 0x97, or (3) 0x98.
How severe is CVE-2012-4356?
Severity scoring for CVE-2012-4356 is pending analysis. The EPSS model estimates a 27.49% probability of exploitation in the next 30 days.
How do I fix CVE-2012-4356?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2012-4356?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST