CVE-2013-0664
Last modified
CVE-2013-0664 is a vulnerability of currently unknown severity. The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests.. EPSS estimates a 3.91% chance of exploitation in the next 30 days.
Description
The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests.
Metrics
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Schneider-Electric | Modicon Quantum Plc | 140noe77111 |
| Schneider-Electric | Modicon Quantum Plc | 140nwm10000 |
| Schneider-Electric | Modicon M340 | bmxnoe0110x |
| Schneider-Electric | Modicon Premium | tsxety5103 |
References
- http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdfUS Government Resource
- http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdfUS Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2013-0664?
How severe is CVE-2013-0664?
How do I fix CVE-2013-0664?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2013
- CVE-2013-0656Buffer overflow in a third-party ActiveX component in Siemen…
- CVE-2013-0657Stack-based buffer overflow in Schneider Electric Interactiv…
- CVE-2013-0658Heap-based buffer overflow in RFManagerService.exe in Schnei…
- CVE-2013-0659The debugging feature on the Siemens CP 1604 and CP 1616 int…
- CVE-2013-0662Multiple stack-based buffer overflows in ModbusDrv.exe in Sc…
- CVE-2013-0663Cross-site request forgery (CSRF) vulnerability on the Schne…
- CVE-2013-0665Schweitzer Engineering Laboratories (SEL) AcSELerator QuickS…
- CVE-2013-0666The configuration utility in MatrikonOPC Security Gateway 1.…
- CVE-2013-0667Cross-site scripting (XSS) vulnerability in the HMI web appl…
- CVE-2013-0668Multiple cross-site scripting (XSS) vulnerabilities in the H…
- CVE-2013-0669The HMI web application in Siemens WinCC (TIA Portal) 11 all…
- CVE-2013-0670CRLF injection vulnerability in the HMI web application in S…
Are you affected by CVE-2013-0664?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST