CVE-2013-0679
Last modified
CVE-2013-0679 is a vulnerability of currently unknown severity. Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.. EPSS estimates a 2.33% chance of exploitation in the next 30 days.
Description
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
Metrics
Weakness Enumeration
Affected Software
| Vendor | Product | Versions | Update |
|---|---|---|---|
| Siemens | Simatic Pcs7 | <= 8.0 | — |
| Siemens | Simatic Pcs7 | 7.1 | Sp3 |
| Siemens | Wincc | <= 7.1 | — |
| Siemens | Wincc | 5.0 | — |
| Siemens | Wincc | 6.0 | — |
| Siemens | Wincc | 7.0 | — |
References
- http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdfUS Government Resource
- http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdfUS Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2013-0679?
How severe is CVE-2013-0679?
How do I fix CVE-2013-0679?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2013
- CVE-2013-0673Directory traversal vulnerability in the web interface in th…
- CVE-2013-0674Buffer overflow in the RegReader ActiveX control in Siemens …
- CVE-2013-0675Buffer overflow in CCEServer (aka the central communications…
- CVE-2013-0676Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0…
- CVE-2013-0677The web server in Siemens WinCC before 7.2, as used in SIMAT…
- CVE-2013-0678Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0…
- CVE-2013-0680Stack-based buffer overflow in the web server in Cogent Real…
- CVE-2013-0681Cogent Real-Time Systems Cogent DataHub before 7.3.0, OPC Da…
- CVE-2013-0682Cogent Real-Time Systems Cogent DataHub before 7.3.0, OPC Da…
- CVE-2013-0683The DataSim and DataPid demonstration clients in Cogent Real…
- CVE-2013-0684SQL injection vulnerability in Invensys Wonderware Informati…
- CVE-2013-0685Invensys Wonderware Information Server (WIS) 4.0 SP1SP1, 4.5…
Are you affected by CVE-2013-0679?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST