CVE-2016-2308
Last modified
CVE-2016-2308 is a vulnerability of currently unknown severity. American Auto-Matrix Aspect-Nexus Building Automation Front-End Solutions application before 3.0.0 and Aspect-Matrix Building Automation Front-End Solutions application store passwords in cleartext, which allows remote attackers to obtain sensitive information by reading a file.. EPSS estimates a 1.36% chance of exploitation in the next 30 days.
Description
American Auto-Matrix Aspect-Nexus Building Automation Front-End Solutions application before 3.0.0 and Aspect-Matrix Building Automation Front-End Solutions application store passwords in cleartext, which allows remote attackers to obtain sensitive information by reading a file.
Metrics
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| American Auto-Matrix | Aspect-Matrix Building Automation Front-End Solutions Application | All versions |
| American Auto-Matrix | Aspect-Nexus Building Automation Front-End Solutions Application | <= 2.0 |
References
- https://ics-cert.us-cert.gov/advisories/ICSA-16-273-01-0Third Party Advisory, US Government Resource
- https://ics-cert.us-cert.gov/advisories/ICSA-16-273-01-0Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2016-2308?
How severe is CVE-2016-2308?
How do I fix CVE-2016-2308?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2016
- CVE-2016-2302Ecava IntegraXor before 5.0 build 4522 allows remote attacke…
- CVE-2016-2303CRLF injection vulnerability in Ecava IntegraXor before 5.0 …
- CVE-2016-2304Ecava IntegraXor before 5.0 build 4522 does not include the …
- CVE-2016-2305Cross-site scripting (XSS) vulnerability in Ecava IntegraXor…
- CVE-2016-2306The HMI web server in Ecava IntegraXor before 5.0 build 4522…
- CVE-2016-2307American Auto-Matrix Aspect-Nexus Building Automation Front-…
- CVE-2016-2309iRZ RUH2 before 2b does not validate firmware patches, which…
- CVE-2016-2310General Electric (GE) Multilink ML800, ML1200, ML1600, and M…9.8
- CVE-2016-2311Black Box AlertWerks ServSensor with firmware before SP473, …
- CVE-2016-2312Turning all screens off in Plasma-workspace and kscreenlocke…
- CVE-2016-2313auth_login.php in Cacti before 0.8.8g allows remote authenti…
- CVE-2016-2314GlobespanVirata ftpd 1.0, as used on Huawei SmartAX MT882 de…
Are you affected by CVE-2016-2308?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST