CVE-2016-9338 is a vulnerability of currently unknown severity. An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. Because of an Incorrect Permission Assignment for Critical Resource, users with administrator privileges may be able to remove all administrative users requiring a factory reset to restore ancillary web server function. EPSS estimates a 2.43% chance of exploitation in the next 30 days.

Description

An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. Because of an Incorrect Permission Assignment for Critical Resource, users with administrator privileges may be able to remove all administrative users requiring a factory reset to restore ancillary web server function. Exploitation of this vulnerability will still allow the affected device to function in its capacity as a controller.

Metrics

EPSS Probability
2.43%

82.1th percentile

Probability of exploitation in the next 30 days. Learn more

Affected Software

VendorProductVersions
Rockwellautomation1763-L16awa Series A<= 14.000
Rockwellautomation1763-L16awa Series B<= 14.000
Rockwellautomation1763-L16bbb Series A<= 14.000
Rockwellautomation1763-L16bbb Series B<= 14.000
Rockwellautomation1763-L16bwa Series A<= 14.000
Rockwellautomation1763-L16bwa Series B<= 14.000
Rockwellautomation1763-L16dwd Series A<= 14.000
Rockwellautomation1763-L16dwd Series B<= 14.000
Rockwellautomation1766-L32awa Series A<= 15.004
Rockwellautomation1766-L32awa Series B<= 15.004
Rockwellautomation1766-L32awaa Series A<= 15.004
Rockwellautomation1766-L32awaa Series B<= 15.004
Rockwellautomation1766-L32bwa Series A<= 15.004
Rockwellautomation1766-L32bwa Series B<= 15.004
Rockwellautomation1766-L32bwaa Series A<= 15.004
Rockwellautomation1766-L32bwaa Series B<= 15.004
Rockwellautomation1766-L32bxb Series A<= 15.004
Rockwellautomation1766-L32bxb Series B<= 15.004
Rockwellautomation1766-L32bxba Series A<= 15.004
Rockwellautomation1766-L32bxba Series B<= 15.004

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2016-9338?
An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. Because of an Incorrect Permission Assignment for Critical Resource, users with administrator privileges may be able to remove all administrative users requiring a factory reset to restore ancillary web server function. Exploitation of this vulnerability will still allow the affected device to function in its capacity as a controller.
How severe is CVE-2016-9338?
Severity scoring for CVE-2016-9338 is pending analysis. The EPSS model estimates a 2.43% probability of exploitation in the next 30 days.
How do I fix CVE-2016-9338?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2016-9338?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST