CVE-2017-1000362
Last modified
CVE-2017-1000362 is a vulnerability of currently unknown severity. The re-key admin monitor was introduced in Jenkins 1.498 and re-encrypted all secrets in JENKINS_HOME with a new key. It also created a backup directory with all old secrets, and the key used to encrypt them. EPSS estimates a 1.72% chance of exploitation in the next 30 days.
Description
The re-key admin monitor was introduced in Jenkins 1.498 and re-encrypted all secrets in JENKINS_HOME with a new key. It also created a backup directory with all old secrets, and the key used to encrypt them. These backups were world-readable and not removed afterwards. Jenkins now deletes the backup directory, if present. Upgrading from before 1.498 will no longer create a backup directory. Administrators relying on file access permissions in their manually created backups are advised to check them for the directory $JENKINS_HOME/jenkins.security.RekeySecretAdminMonitor/backups, and delete it if present.
Metrics
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Jenkins | Jenkins | <= 1.498 |
References
- https://jenkins.io/security/advisory/2017-02-01/Vendor Advisory
- https://jenkins.io/security/advisory/2017-02-01/Vendor Advisory