CVE-2017-8230

UnknownEPSS 1.66%

Last modified

CVE-2017-8230 is a vulnerability of currently unknown severity. On Amcrest IPM-721S V2.420.AC00.16.R.20160909 devices, the users on the device are divided into 2 groups "admin" and "user". However, as a part of security analysis it was identified that a low privileged user who belongs to the "user" group and who has access to login in to the web administrative interface of the device can add a new administrative user to the interface using HTTP APIs provided by the device and perform all the actions as an administrative user by using that account. EPSS estimates a 1.66% chance of exploitation in the next 30 days.

Description

On Amcrest IPM-721S V2.420.AC00.16.R.20160909 devices, the users on the device are divided into 2 groups "admin" and "user". However, as a part of security analysis it was identified that a low privileged user who belongs to the "user" group and who has access to login in to the web administrative interface of the device can add a new administrative user to the interface using HTTP APIs provided by the device and perform all the actions as an administrative user by using that account. If the firmware version V2.420.AC00.16.R 9/9/2016 is dissected using binwalk tool, one obtains a _user-x.squashfs.img.extracted archive which contains the filesystem set up on the device that many of the binaries in the /usr folder. The binary "sonia" is the one that has the vulnerable functions that performs the various action described in HTTP APIs. If one opens this binary in IDA-pro one will notice that this follows a ARM little endian format. The function at address 0x00429084 in IDA pro is the one that processes the HTTP API request for "addUser" action. If one traces the calls to this function, it can be clearly seen that the function sub_ 41F38C at address 0x0041F588 parses the call received from the browser and passes it to the "addUser" function without any authorization check.

Metrics

EPSS Probability
1.66%

73.7th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
AmcrestIpm-721s Firmware<= 2.420.ac00.16.r.20160909

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2017-8230?
On Amcrest IPM-721S V2.420.AC00.16.R.20160909 devices, the users on the device are divided into 2 groups "admin" and "user". However, as a part of security analysis it was identified that a low privileged user who belongs to the "user" group and who has access to login in to the web administrative interface of the device can add a new administrative user to the interface using HTTP APIs provided by the device and perform all the actions as an administrative user by using that account. If the firmware version V2.420.AC00.16.R 9/9/2016 is dissected using binwalk tool, one obtains a _user-x.squashfs.img.extracted archive which contains the filesystem set up on the device that many of the binaries in the /usr folder. The binary "sonia" is the one that has the vulnerable functions that performs the various action described in HTTP APIs. If one opens this binary in IDA-pro one will notice that this follows a ARM little endian format. The function at address 0x00429084 in IDA pro is the one that processes the HTTP API request for "addUser" action. If one traces the calls to this function, it can be clearly seen that the function sub_ 41F38C at address 0x0041F588 parses the call received from the browser and passes it to the "addUser" function without any authorization check.
How severe is CVE-2017-8230?
Severity scoring for CVE-2017-8230 is pending analysis. The EPSS model estimates a 1.66% probability of exploitation in the next 30 days.
How do I fix CVE-2017-8230?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2017-8230?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST