CVE-2017-8408

UnknownEPSS 5.12%

Last modified

CVE-2017-8408 is a vulnerability of currently unknown severity. An issue was discovered on D-Link DCS-1130 devices. The device provides a user with the capability of setting a SMB folder for the video clippings recorded by the device. EPSS estimates a 5.12% chance of exploitation in the next 30 days.

Description

An issue was discovered on D-Link DCS-1130 devices. The device provides a user with the capability of setting a SMB folder for the video clippings recorded by the device. It seems that the GET parameters passed in this request (to test if SMB credentials and hostname sent to the device work properly) result in being passed as commands to a "system" API in the function and thus result in command injection on the device. If the firmware version is dissected using binwalk tool, we obtain a cramfs-root archive which contains the filesystem set up on the device that contains all the binaries. The binary "cgibox" is the one that has the vulnerable function "sub_7EAFC" that receives the values sent by the GET request. If we open this binary in IDA-pro we will notice that this follows a ARM little endian format. The function sub_7EAFC in IDA pro is identified to be receiving the values sent in the GET request and the value set in GET parameter "user" is extracted in function sub_7E49C which is then passed to the vulnerable system API call.

Metrics

EPSS Probability
5.12%

91.3th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
DlinkDcs-1130 FirmwareAll versions

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2017-8408?
An issue was discovered on D-Link DCS-1130 devices. The device provides a user with the capability of setting a SMB folder for the video clippings recorded by the device. It seems that the GET parameters passed in this request (to test if SMB credentials and hostname sent to the device work properly) result in being passed as commands to a "system" API in the function and thus result in command injection on the device. If the firmware version is dissected using binwalk tool, we obtain a cramfs-root archive which contains the filesystem set up on the device that contains all the binaries. The binary "cgibox" is the one that has the vulnerable function "sub_7EAFC" that receives the values sent by the GET request. If we open this binary in IDA-pro we will notice that this follows a ARM little endian format. The function sub_7EAFC in IDA pro is identified to be receiving the values sent in the GET request and the value set in GET parameter "user" is extracted in function sub_7E49C which is then passed to the vulnerable system API call.
How severe is CVE-2017-8408?
Severity scoring for CVE-2017-8408 is pending analysis. The EPSS model estimates a 5.12% probability of exploitation in the next 30 days.
How do I fix CVE-2017-8408?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2017-8408?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST