CVE-2018-11454

UnknownEPSS 0.44%

Last modified

CVE-2018-11454 is a vulnerability of currently unknown severity. A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. EPSS estimates a 0.44% chance of exploitation in the next 30 days.

Description

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device.

Metrics

EPSS Probability
0.44%

35.3th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
SiemensSimatic Step 7 \(Tia Portal\)10.0
SiemensSimatic Step 7 \(Tia Portal\)11.0
SiemensSimatic Step 7 \(Tia Portal\)12.0
SiemensSimatic Step 7 \(Tia Portal\)13.0
SiemensSimatic Step 7 \(Tia Portal\)14.0
SiemensSimatic Step 7 \(Tia Portal\)15.0
SiemensSimatic Wincc \(Tia Portal\)10.0
SiemensSimatic Wincc \(Tia Portal\)11.0
SiemensSimatic Wincc \(Tia Portal\)12.0
SiemensSimatic Wincc \(Tia Portal\)13.0
SiemensSimatic Wincc \(Tia Portal\)14.0
SiemensSimatic Wincc \(Tia Portal\)15.0

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2018-11454?
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device.
How severe is CVE-2018-11454?
Severity scoring for CVE-2018-11454 is pending analysis. The EPSS model estimates a 0.44% probability of exploitation in the next 30 days.
How do I fix CVE-2018-11454?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2018-11454?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST