CVE-2018-4840

UnknownEPSS 1.80%

Last modified

CVE-2018-4840 is a vulnerability of currently unknown severity. A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.. EPSS estimates a 1.80% chance of exploitation in the next 30 days.

Description

A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.

Metrics

EPSS Probability
1.80%

75.7th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
SiemensSiprotec Compact 7sj80 Firmware< 4.77
SiemensSiprotec Compact 7sk80 Firmware< 4.77
SiemensSiprotec 4 7sj66 Firmware< 4.30
SiemensDigsi 4< 4.92
SiemensEn100 Ethernet Module Iec 104 FirmwareAll versions
SiemensEn100 Ethernet Module Dnp3 FirmwareAll versions
SiemensEn100 Ethernet Module Modbus Tcp FirmwareAll versions
SiemensEn100 Ethernet Module Profinet Io FirmwareAll versions
SiemensEn100 Ethernet Module Iec 61850 Firmware< 4.30

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2018-4840?
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.
How severe is CVE-2018-4840?
Severity scoring for CVE-2018-4840 is pending analysis. The EPSS model estimates a 1.80% probability of exploitation in the next 30 days.
How do I fix CVE-2018-4840?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2018-4840?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST