CVE-2018-5452 is a high-severity vulnerability rated 7.5/10 on the CVSS scale. A Stack-based Buffer Overflow issue was discovered in Emerson Process Management ControlWave Micro Process Automation Controller: ControlWave Micro [ProConOS v.4.01.280] firmware: CWM v.05.78.00 and prior. A stack-based buffer overflow vulnerability caused by sending crafted packets on Port 20547 could force the PLC to change its state into halt mode.. EPSS estimates a 2.08% chance of exploitation in the next 30 days.
Description
A Stack-based Buffer Overflow issue was discovered in Emerson Process Management ControlWave Micro Process Automation Controller: ControlWave Micro [ProConOS v.4.01.280] firmware: CWM v.05.78.00 and prior. A stack-based buffer overflow vulnerability caused by sending crafted packets on Port 20547 could force the PLC to change its state into halt mode.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Emerson | Controlwave Micro Firmware | <= 05.78.00 |
References
- http://www.securityfocus.com/bid/103180Third Party Advisory, VDB Entry
- https://ics-cert.us-cert.gov/advisories/ICSA-18-058-03Third Party Advisory, US Government Resource
- http://www.securityfocus.com/bid/103180Third Party Advisory, VDB Entry
- https://ics-cert.us-cert.gov/advisories/ICSA-18-058-03Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2018-5452?
How severe is CVE-2018-5452?
How do I fix CVE-2018-5452?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2018
- CVE-2018-5445A Path Traversal issue was discovered in Advantech WebAccess…
- CVE-2018-5446Medtronic 2090 CareLink Programmer uses a per-product user…4.9
- CVE-2018-5447An Improper Input Validation issue was discovered in Nari PC…
- CVE-2018-5448Medtronic 2090 CareLink Programmer’s software deployment net…4.8
- CVE-2018-5449A NULL Pointer Dereference issue was discovered in Moxa OnCe…
- CVE-2018-5451In Philips Alice 6 System version R8.0.2 or prior, when an a…
- CVE-2018-5453An Improper Handling of Length Parameter Inconsistency issue…
- CVE-2018-5454Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x…
- CVE-2018-5455A Reliance on Cookies without Validation and Integrity Check…
- CVE-2018-5457A uncontrolled search path element issue was discovered in V…
- CVE-2018-5458Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x…
- CVE-2018-5459An Improper Authentication issue was discovered in WAGO PFC2…
Are you affected by CVE-2018-5452?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST