CVE-2019-10972
Last modified
CVE-2019-10972 is a medium-severity vulnerability rated 5.5/10 on the CVSS scale. Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). EPSS estimates a 0.89% chance of exploitation in the next 30 days.
Description
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted.
Metrics
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Mitsubishielectric | Electric Fr Configurator2 | <= 1.16s |
References
- https://www.us-cert.gov/ics/advisories/icsa-19-204-01Third Party Advisory, US Government Resource
- https://www.us-cert.gov/ics/advisories/icsa-19-204-01Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2019-10972?
How severe is CVE-2019-10972?
How do I fix CVE-2019-10972?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2019
- CVE-2019-10967In Emerson Ovation OCR400 Controller 3.3.1 and earlier, a st…8.8
- CVE-2019-10968Philips Holter 2010 Plus, all versions. A vulnerability has …4.4
- CVE-2019-10969Moxa EDR 810, all versions 5.1 and prior, allows an authenti…7.2
- CVE-2019-1097An information disclosure vulnerability exists when DirectWr…
- CVE-2019-10970In Rockwell Automation PanelView 5510 (all versions manufact…9.8
- CVE-2019-10971The application (Network Configurator for DeviceNet Safety 3…
- CVE-2019-10973Quest KACE, all versions prior to version 8.0.x, 8.1.x, and …
- CVE-2019-10974NREL EnergyPlus, Versions 8.6.0 and possibly prior versions,…5.5
- CVE-2019-10975An out-of-bounds read vulnerability has been identified in F…
- CVE-2019-10976Mitsubishi Electric FR Configurator2, Version 1.16S and prio…
- CVE-2019-10977In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E…7.5
- CVE-2019-10978Red Lion Controls Crimson, version 3.0 and prior and version…7.8
Are you affected by CVE-2019-10972?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST