CVE-2019-13529
Last modified
CVE-2019-13529 is a high-severity vulnerability rated 8.8/10 on the CVSS scale. An attacker could send a malicious link to an authenticated operator, which may allow remote attackers to perform actions with the permissions of the user on the Sunny WebBox Firmware Version 1.6 and prior. This device uses IP addresses to maintain communication after a successful login, which would increase the ease of exploitation.. EPSS estimates a 2.23% chance of exploitation in the next 30 days.
Description
An attacker could send a malicious link to an authenticated operator, which may allow remote attackers to perform actions with the permissions of the user on the Sunny WebBox Firmware Version 1.6 and prior. This device uses IP addresses to maintain communication after a successful login, which would increase the ease of exploitation.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Sma | Sunny Webbox Firmware | <= 1.6 |
References
- https://www.us-cert.gov/ics/advisories/icsa-19-281-01Third Party Advisory, US Government Resource
- https://www.us-cert.gov/ics/advisories/icsa-19-281-01Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2019-13529?
How severe is CVE-2019-13529?
How do I fix CVE-2019-13529?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2019
- CVE-2019-13523In Honeywell Performance IP Cameras and Performance NVRs, th…5.3
- CVE-2019-13524GE PACSystems RX3i CPE100/115: All versions prior to R9.85,C…7.5
- CVE-2019-13525In IP-AK2 Access Control Panel Version 1.04.07 and prior, th…5.3
- CVE-2019-13526Datalogic AV7000 Linear barcode scanner all versions prior t…
- CVE-2019-13527In Rockwell Automation Arena Simulation Software Cat. 9502-A…7.8
- CVE-2019-13528A specific utility may allow an attacker to gain read access…4.4
- CVE-2019-1353An issue was found in Git before v2.24.1, v2.23.1, v2.22.2, …9.8
- CVE-2019-13530Philips IntelliVue WLAN, portable patient monitors, WLAN Ver…7.2
- CVE-2019-13531In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) vers…4.6
- CVE-2019-13532CODESYS V3 web server, all versions prior to 3.5.14.10, allo…7.5
- CVE-2019-13533In Omron PLC CJ series, all versions, and Omron PLC CS serie…8.1
- CVE-2019-13534Philips IntelliVue WLAN, portable patient monitors, WLAN Ver…7.2
Are you affected by CVE-2019-13529?