CVE-2019-13924

MEDIUMCVSS 5.4/10EPSS 0.80%

Last modified

CVE-2019-13924 is a medium-severity vulnerability rated 5.4/10 on the CVSS scale. A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. EPSS estimates a 0.80% chance of exploitation in the next 30 days.

Description

A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.

Metrics

CVSS 3.1
5.4/10

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N

EPSS Probability
0.80%

52.1th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
SiemensScalance Xc-200 Firmware< 5.2.4
SiemensScalance Xf-200 Firmware< 5.2.4
SiemensScalance Xp-200 Firmware< 5.2.4
SiemensScalance X-200irt FirmwareAll versions
SiemensScalance Xb-200 Firmware< 5.2.4
SiemensScalance Xr-300wg Firmware< 4.1.3
SiemensScalance X-300 Firmware< 4.1.3
SiemensScalance Xr-300 Firmware< 4.1.3

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2019-13924?
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
How severe is CVE-2019-13924?
CVE-2019-13924 has a CVSS score of 5.4/10 (MEDIUM severity). The EPSS model estimates a 0.80% probability of exploitation in the next 30 days.
How do I fix CVE-2019-13924?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2019-13924?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST