CVE-2019-19994
CRITICALCVSS 9.8/10EPSS 4.84%
Last modified
CVE-2019-19994 is a critical-severity vulnerability rated 9.8/10 on the CVSS scale. An issue was discovered in Selesta Visual Access Manager (VAM) 4.15.0 through 4.29. It allows blind Command Injection. EPSS estimates a 4.84% chance of exploitation in the next 30 days.
Description
An issue was discovered in Selesta Visual Access Manager (VAM) 4.15.0 through 4.29. It allows blind Command Injection. An attacker without authentication is able to execute arbitrary operating system command by injecting the vulnerable parameter in the PHP Web page /common/vam_monitor_sap.php.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Seling | Visual Access Manager | >= 4.15.0, <= 4.29.0 |
References
- https://www.seling.it/Product
- https://www.seling.it/product/vam/Product, Vendor Advisory
- https://www.telecomitalia.com/tit/it/innovazione/cybersecurity/red-team.htmlExploit, Third Party Advisory
- https://www.seling.it/Product
- https://www.seling.it/product/vam/Product, Vendor Advisory
- https://www.telecomitalia.com/tit/it/innovazione/cybersecurity/red-team.htmlExploit, Third Party Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2019-19994?
An issue was discovered in Selesta Visual Access Manager (VAM) 4.15.0 through 4.29. It allows blind Command Injection. An attacker without authentication is able to execute arbitrary operating system command by injecting the vulnerable parameter in the PHP Web page /common/vam_monitor_sap.php.
How severe is CVE-2019-19994?
CVE-2019-19994 has a CVSS score of 9.8/10 (CRITICAL severity). The EPSS model estimates a 4.84% probability of exploitation in the next 30 days.
How do I fix CVE-2019-19994?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2019
- CVE-2019-19989An issue was discovered in Selesta Visual Access Manager (VA…7.5
- CVE-2019-1999In binder_alloc_free_page of binder_alloc.c, there is a poss…7.8
- CVE-2019-19990An issue was discovered in Selesta Visual Access Manager (VA…5.4
- CVE-2019-19991An issue was discovered in Selesta Visual Access Manager (VA…5.4
- CVE-2019-19992An issue was discovered in Selesta Visual Access Manager (VA…6.5
- CVE-2019-19993An issue was discovered in Selesta Visual Access Manager (VA…5.3
- CVE-2019-19995A CSRF issue was discovered on Intelbras IWR 3000N 1.8.7 dev…8.8
- CVE-2019-19996An issue was discovered on Intelbras IWR 3000N 1.8.7 devices…7.5
- CVE-2019-19998Xiuno BBS 4.0 allows XXE via plugin/xn_wechat_public/route/t…7.5
- CVE-2019-19999Halo before 1.2.0-beta.1 allows Server Side Template Injecti…7.2
- CVE-2019-2000In several functions of binder.c, there is possible memory c…
- CVE-2019-20000The malware scan function in BullGuard Premium Protection 20…5.9
Are you affected by CVE-2019-19994?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST