CVE-2019-6572 is a critical-severity vulnerability rated 9.1/10 on the CVSS scale. A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. EPSS estimates a 2.72% chance of exploitation in the next 30 days.
Description
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Simatic Hmi Comfort Panels Firmware | < 15.1 |
| Siemens | Simatic Hmi Comfort Outdoor Panels Firmware | < 15.1 |
| Siemens | Simatic Hmi Ktp Mobile Panels Ktp400f Firmware | < 15.1 |
| Siemens | Simatic Hmi Ktp Mobile Panels Ktp700 Firmware | < 15.1 |
| Siemens | Simatic Hmi Ktp Mobile Panels Ktp700f Firmware | < 15.1 |
| Siemens | Simatic Hmi Ktp Mobile Panels Ktp900 Firmware | < 15.1 |
| Siemens | Simatic Hmi Ktp Mobile Panels Ktp900f Firmware | < 15.1 |
| Siemens | Simatic Wincc \(Tia Portal\) | < 15.1 |
| Siemens | Simatic Wincc Runtime | < 15.1 |
| Siemens | Simatic Hmi Tp Firmware | All versions |
| Siemens | Simatic Hmi Mp Firmware | All versions |
| Siemens | Simatic Hmi Op Firmware | All versions |
References
- http://www.securityfocus.com/bid/108412Third Party Advisory, VDB Entry
- https://www.us-cert.gov/ics/advisories/ICSA-19-134-09Third Party Advisory, US Government Resource
- http://www.securityfocus.com/bid/108412Third Party Advisory, VDB Entry
- https://www.us-cert.gov/ics/advisories/ICSA-19-134-09Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2019-6572?
How severe is CVE-2019-6572?
How do I fix CVE-2019-6572?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2019
- CVE-2019-6566GE Communicator, all versions prior to 4.0.517, allows a non…7.8
- CVE-2019-6567A vulnerability has been identified in SCALANCE X-200 switch…5.5
- CVE-2019-6568The webserver of the affected devices contains a vulnerabili…7.5
- CVE-2019-6569The monitor barrier of the affected products insufficiently …9.1
- CVE-2019-6570A vulnerability has been identified in SINEMA Remote Connect…8.8
- CVE-2019-6571A vulnerability has been identified in SIEMENS LOGO!8 (6ED10…7.5
- CVE-2019-6574A vulnerability has been identified in SINAMICS PERFECT HARM…7.5
- CVE-2019-6575A vulnerability has been identified in SIMATIC CP 443-1 OPC …7.5
- CVE-2019-6576A vulnerability has been identified in SIMATIC HMI Comfort P…6.5
- CVE-2019-6577A vulnerability has been identified in SIMATIC HMI Comfort P…
- CVE-2019-6578A vulnerability has been identified in SINAMICS PERFECT HARM…7.5
- CVE-2019-6579A vulnerability has been identified in Spectrum Power 4 (wit…9.8
Are you affected by CVE-2019-6572?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST