CVE-2020-12003

HIGHCVSS 7.5/10EPSS 5.23%

Last modified

CVE-2020-12003 is a high-severity vulnerability rated 7.5/10 on the CVSS scale. FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. EPSS estimates a 5.23% chance of exploitation in the next 30 days.

Description

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive.

Metrics

CVSS 3.1
7.5/10

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

EPSS Probability
5.23%

91.5th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
RockwellautomationFactorytalk Linx6.00
RockwellautomationFactorytalk Linx6.10
RockwellautomationFactorytalk Linx6.11
RockwellautomationRslinx Classic<= 4.11.00

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2020-12003?
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive.
How severe is CVE-2020-12003?
CVE-2020-12003 has a CVSS score of 7.5/10 (HIGH severity). The EPSS model estimates a 5.23% probability of exploitation in the next 30 days.
How do I fix CVE-2020-12003?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2020-12003?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST