CVE-2020-1204
Last modified
CVE-2020-1204 is a high-severity vulnerability rated 7.1/10 on the CVSS scale. An elevation of privilege vulnerability exists when Windows Mobile Device Management (MDM) Diagnostics improperly handles junctions, aka 'Windows Mobile Device Management Diagnostics Elevation of Privilege Vulnerability'.. EPSS estimates a 0.76% chance of exploitation in the next 30 days.
Description
An elevation of privilege vulnerability exists when Windows Mobile Device Management (MDM) Diagnostics improperly handles junctions, aka 'Windows Mobile Device Management Diagnostics Elevation of Privilege Vulnerability'.
Metrics
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Microsoft | Windows 10 | 1809 |
| Microsoft | Windows 10 | 1903 |
| Microsoft | Windows 10 | 1909 |
| Microsoft | Windows 10 | 2004 |
| Microsoft | Windows Server 2016 | 1903 |
| Microsoft | Windows Server 2016 | 1909 |
| Microsoft | Windows Server 2016 | 2004 |
| Microsoft | Windows Server 2019 | All versions |
References
- https://portal.msrc.microsoft.com/en-US/security-guidance/advisory/CVE-2020-1204Patch, Vendor Advisory
- https://portal.msrc.microsoft.com/en-US/security-guidance/advisory/CVE-2020-1204Patch, Vendor Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2020-1204?
How severe is CVE-2020-1204?
How do I fix CVE-2020-1204?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2020
- CVE-2020-12034Products that use EDS Subsystem: Version 28.0.1 and prior (F…8.2
- CVE-2020-12035Baxter PrismaFlex all versions, PrisMax all versions prior t…4.9
- CVE-2020-12036Baxter PrismaFlex all versions, PrisMax all versions prior t…7.5
- CVE-2020-12037Baxter PrismaFlex all versions, PrisMax all versions prior t…7.5
- CVE-2020-12038Products that use EDS Subsystem: Version 28.0.1 and prior (F…5.5
- CVE-2020-12039Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion…2.4
- CVE-2020-12040Sigma Spectrum Infusion System v's6.x (model 35700BAX) and B…9.8
- CVE-2020-12041The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v2…9.4
- CVE-2020-12042Opto 22 SoftPAC Project Version 9.6 and prior. Paths specifi…6.5
- CVE-2020-12043The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v2…9.8
- CVE-2020-12045The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v2…9.8
- CVE-2020-12046Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC’s fir…5.7
Are you affected by CVE-2020-1204?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST
