CVE-2020-14493
HIGHCVSS 8.8/10EPSS 1.68%
Last modified
CVE-2020-14493 is a high-severity vulnerability rated 8.8/10 on the CVSS scale. A low-privilege user may use SQL syntax to write arbitrary files to the OpenClinic GA 5.09.02 and 5.89.05b server, which may allow the execution of arbitrary commands.. EPSS estimates a 1.68% chance of exploitation in the next 30 days.
Description
A low-privilege user may use SQL syntax to write arbitrary files to the OpenClinic GA 5.09.02 and 5.89.05b server, which may allow the execution of arbitrary commands.
Metrics
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Openclinic Ga Project | Openclinic Ga | 5.09.02 |
| Openclinic Ga Project | Openclinic Ga | 5.89.05b |
References
- https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01Third Party Advisory, US Government Resource
- https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2020-14493?
A low-privilege user may use SQL syntax to write arbitrary files to the OpenClinic GA 5.09.02 and 5.89.05b server, which may allow the execution of arbitrary commands.
How severe is CVE-2020-14493?
CVE-2020-14493 has a CVSS score of 8.8/10 (HIGH severity). The EPSS model estimates a 1.68% probability of exploitation in the next 30 days.
How do I fix CVE-2020-14493?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2020
- CVE-2020-14488OpenClinic GA 5.09.02 and 5.89.05b does not properly verify …8.8
- CVE-2020-14489OpenClinic GA 5.09.02 and 5.89.05b stores passwords using in…7.5
- CVE-2020-1449A remote code execution vulnerability exists in Microsoft Pr…7.8
- CVE-2020-14490OpenClinic GA 5.09.02 and 5.89.05b includes arbitrary local …8.8
- CVE-2020-14491OpenClinic GA versions 5.09.02 and 5.89.05b do not properly …6.5
- CVE-2020-14492OpenClinic GA 5.09.02 and 5.89.05b does not properly neutral…6.1
- CVE-2020-14494OpenClinic GA versions 5.09.02 and 5.89.05b contain an authe…9.8
- CVE-2020-14495Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultID…
- CVE-2020-14496Successful exploitation of this vulnerability for multiple M…9.8
- CVE-2020-14497Advantech iView, versions 5.6 and prior, contains multiple S…9.8
- CVE-2020-14498HMS Industrial Networks AB eCatcher all versions prior to 6.…10
- CVE-2020-14499Advantech iView, versions 5.6 and prior, has an improper acc…7.5
Are you affected by CVE-2020-14493?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST