CVE-2020-15798 is a critical-severity vulnerability rated 9.8/10 on the CVSS scale. A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). EPSS estimates a 5.18% chance of exploitation in the next 30 days.

Description

A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)

Metrics

CVSS 3.1
9.8/10

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

EPSS Probability
5.18%

91.4th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
SiemensSimatic Hmi Comfort Panels Firmware< 16.0
SiemensSimatic Hmi Comfort Panels Firmware16.0
SiemensSimatic Hmi Ktp Mobile Panels Firmware< 16.0
SiemensSimatic Hmi Ktp Mobile Panels Firmware16.0
SiemensSinamics Gh150 FirmwareAll versions
SiemensSinamics Gl150 FirmwareAll versions
SiemensSinamics Gm150 FirmwareAll versions
SiemensSinamics Sh150 FirmwareAll versions
SiemensSinamics Sl150 FirmwareAll versions
SiemensSinamics Sm150 FirmwareAll versions
SiemensSinamics Sm120 FirmwareAll versions
SiemensSinamics Sm150i FirmwareAll versions

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2020-15798?
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
How severe is CVE-2020-15798?
CVE-2020-15798 has a CVSS score of 9.8/10 (CRITICAL severity). The EPSS model estimates a 5.18% probability of exploitation in the next 30 days.
How do I fix CVE-2020-15798?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2020-15798?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST