CVE-2020-16217
Last modified
CVE-2020-16217 is a high-severity vulnerability rated 7.8/10 on the CVSS scale. Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. A double free vulnerability caused by processing specially crafted project files may allow remote code execution, disclosure/modification of information, or cause the application to crash.. EPSS estimates a 2.87% chance of exploitation in the next 30 days.
Description
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. A double free vulnerability caused by processing specially crafted project files may allow remote code execution, disclosure/modification of information, or cause the application to crash.
Metrics
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Advantech | Webaccess\/Hmi Designer | <= 2.1.9.31 |
References
- https://us-cert.cisa.gov/ics/advisories/icsa-20-219-02Third Party Advisory, US Government Resource
- https://www.zerodayinitiative.com/advisories/ZDI-20-952/Third Party Advisory, VDB Entry
- https://us-cert.cisa.gov/ics/advisories/icsa-20-219-02Third Party Advisory, US Government Resource
- https://www.zerodayinitiative.com/advisories/ZDI-20-952/Third Party Advisory, VDB Entry
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2020-16217?
How severe is CVE-2020-16217?
How do I fix CVE-2020-16217?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2020
- CVE-2020-16211Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prio…5.5
- CVE-2020-16212In Patient Information Center iX (PICiX) Versions B.02, C.02…6.8
- CVE-2020-16213Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prio…7.8
- CVE-2020-16214In Patient Information Center iX (PICiX) Versions B.02, C.02…5
- CVE-2020-16215Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prio…7.8
- CVE-2020-16216In IntelliVue patient monitors MX100, MX400-550, MX600, MX70…6.5
- CVE-2020-16218In Patient Information Center iX (PICiX) Versions B.02, C.02…3.5
- CVE-2020-16219Delta Electronics TPEditor Versions 1.97 and prior. An out-o…7.8
- CVE-2020-1622A local, authenticated user with shell can obtain the hashed…5.5
- CVE-2020-16220In Patient Information Center iX (PICiX) Versions C.02, C.03…4.3
- CVE-2020-16221Delta Electronics TPEditor Versions 1.97 and prior. A stack-…7.8
- CVE-2020-16222In Patient Information Center iX (PICiX) Version B.02, C.02,…8.8
Are you affected by CVE-2020-16217?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST