CVE-2020-27737
Last modified
CVE-2020-27737 is a medium-severity vulnerability rated 6.5/10 on the CVSS scale. A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. EPSS estimates a 3.57% chance of exploitation in the next 30 days.
Description
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure.
Metrics
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Simotics Connect 400 Firmware | < 0.5.0.0 |
| Siemens | Nucleus Net | All versions |
| Siemens | Nucleus Readystart V3 | < 2017.02.3 |
| Siemens | Nucleus Readystart V4 | < 4.1.0 |
| Siemens | Nucleus Source Code | All versions |
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdfPatch, Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdfPatch, Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdfPatch, Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdfPatch, Vendor Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2020-27737?
How severe is CVE-2020-27737?
How do I fix CVE-2020-27737?
Are you affected by CVE-2020-27737?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST