CVE-2020-7562

HIGHCVSS 8.1/10EPSS 0.88%

Last modified

CVE-2020-7562 is a high-severity vulnerability rated 8.1/10 on the CVSS scale. A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file on the controller over FTP.. EPSS estimates a 0.88% chance of exploitation in the next 30 days.

Description

A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file on the controller over FTP.

Metrics

CVSS 3.1
8.1/10

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H

EPSS Probability
0.88%

54.6th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
Schneider-ElectricModicon Tsxety4103 FirmwareAll versions
Schneider-ElectricModicon Tsxety5103 FirmwareAll versions
Schneider-ElectricModicon Tsxp574634 FirmwareAll versions
Schneider-ElectricModicon Tsxp575634 FirmwareAll versions
Schneider-ElectricModicon Tsxp576634 FirmwareAll versions
Schneider-ElectricModicon Quantum 140noe77101 FirmwareAll versions
Schneider-ElectricModicon Quantum 140noe77111 FirmwareAll versions
Schneider-ElectricModicon Quantum 140noc78100 FirmwareAll versions
Schneider-ElectricModicon Quantum 140cpu65150 FirmwareAll versions
Schneider-ElectricModicon Quantum 140cpu65150c FirmwareAll versions
Schneider-ElectricModicon Quantum 140cpu65160c FirmwareAll versions
Schneider-ElectricModicon Quantum 140cpu65160 FirmwareAll versions
Schneider-ElectricModicon M340 Bmx P34-2010 FirmwareAll versions
Schneider-ElectricModicon M340 Bmx P34-2030 FirmwareAll versions
Schneider-ElectricModicon M340 Bmx Noc 0401 FirmwareAll versions
Schneider-ElectricModicon M340 Bmx Noe 0100 FirmwareAll versions
Schneider-ElectricModicon M340 Bmx Noe 0100h FirmwareAll versions
Schneider-ElectricModicon M340 Bmx Noe 0110 FirmwareAll versions
Schneider-ElectricModicon M340 Bmx Noe 0110h FirmwareAll versions
Schneider-ElectricModicon M340 Bmx Nor 0200h FirmwareAll versions

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2020-7562?
A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file on the controller over FTP.
How severe is CVE-2020-7562?
CVE-2020-7562 has a CVSS score of 8.1/10 (HIGH severity). The EPSS model estimates a 0.88% probability of exploitation in the next 30 days.
How do I fix CVE-2020-7562?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2020-7562?