CVE-2021-20588
Last modified
CVE-2021-20588 is a critical-severity vulnerability rated 9.8/10 on the CVSS scale. Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) versions 1.003D and prior, iQ Monozukuri Process Remote Monitoring (Data Transfer) versions 1.002C and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior, and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition on the software products, and possibly to execute a malicious code on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.. EPSS estimates a 5.86% chance of exploitation in the next 30 days.
Description
Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) versions 1.003D and prior, iQ Monozukuri Process Remote Monitoring (Data Transfer) versions 1.002C and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior, and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition on the software products, and possibly to execute a malicious code on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Mitsubishielectric | C Controller Module Setting And Monitoring Tool | All versions |
| Mitsubishielectric | Cpu Module Logging Configuration Tool | <= 1.112r |
| Mitsubishielectric | Cw Configurator | <= 1.011m |
| Mitsubishielectric | Data Transfer | <= 3.44w |
| Mitsubishielectric | Ezsocket | All versions |
| Mitsubishielectric | Fr Configurator | All versions |
| Mitsubishielectric | Fr Configurator Sw3 | All versions |
| Mitsubishielectric | Fr Configurator2 | <= 1.24a |
| Mitsubishielectric | Gt Designer3 | <= 1.250l |
| Mitsubishielectric | Gt Softgot1000 | <= 3.245f |
| Mitsubishielectric | Gt Softgot2000 | <= 1.250l |
| Mitsubishielectric | Gx Configurator-Dp | <= 7.14q |
| Mitsubishielectric | Gx Configurator-Qp | All versions |
| Mitsubishielectric | Gx Developer | <= 8.506c |
| Mitsubishielectric | Gx Explorer | All versions |
| Mitsubishielectric | Gx Iec Developer | All versions |
| Mitsubishielectric | Gx Logviewer | <= 1.115u |
| Mitsubishielectric | Gx Remoteservice-I | All versions |
| Mitsubishielectric | Gx Works2 | <= 1.597x |
| Mitsubishielectric | Gx Works3 | <= 1.070y |
| Mitsubishielectric | Iq Monozukuri Andon | All versions |
| Mitsubishielectric | Iq Monozukuri Process Remote Monitoring | All versions |
| Mitsubishielectric | M Commdtm-Hart | All versions |
| Mitsubishielectric | M Commdtm-Io-Link | All versions |
| Mitsubishielectric | Melfa-Works | <= 4.4 |
| Mitsubishielectric | Melsec Wincpu Setting Utility | All versions |
| Mitsubishielectric | Melsoft Em Software Development Kit | All versions |
| Mitsubishielectric | Melsoft Navigator | <= 2.74c |
| Mitsubishielectric | Mh11 Settingtool Version2 | <= 2.004e |
| Mitsubishielectric | Mi Configurator | All versions |
| Mitsubishielectric | Mt Works2 | <= 1.167z |
| Mitsubishielectric | Mx Component | <= 5.001b |
| Mitsubishielectric | Network Interface Board Cc-Link | All versions |
| Mitsubishielectric | Network Interface Board Cc Ie Control Utility | All versions |
| Mitsubishielectric | Network Interface Board Cc Ie Field Utility | All versions |
| Mitsubishielectric | Network Interface Board Mneth Utility | All versions |
| Mitsubishielectric | Px Developer | <= 1.53f |
| Mitsubishielectric | Rt Toolbox2 | <= 3.73b |
| Mitsubishielectric | Rt Toolbox3 | <= 1.82l |
| Mitsubishielectric | Setting\/Monitoring Tools For The C Controller Module | All versions |
| Mitsubishielectric | Slmp Data Collector | <= 1.04e |
References
- https://jvn.jp/vu/JVNVU92330101/index.htmlThird Party Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2021-20588?
How severe is CVE-2021-20588?
How do I fix CVE-2021-20588?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2021
- CVE-2021-20582IBM Security Secret Server up to 11.0 stores sensitive infor…5.3
- CVE-2021-20583IBM Security Verify (IBM Security Verify Privilege Vault 10.…4.9
- CVE-2021-20584IBM Sterling File Gateway 2.2.0.0 through 6.1.1.0 could allo…7.5
- CVE-2021-20585IBM Security Verify Access 20.07 could disclose sensitive in…5.3
- CVE-2021-20586Resource management errors vulnerability in a robot controll…7.5
- CVE-2021-20587Heap-based buffer overflow vulnerability in Mitsubishi Elect…9.8
- CVE-2021-20589Buffer access with incorrect length value vulnerability in G…7.5
- CVE-2021-2059Vulnerability in the Oracle iStore product of Oracle E-Busin…5.3
- CVE-2021-20590Improper authentication vulnerability in GOT2000 series GT27…7.5
- CVE-2021-20591Uncontrolled Resource Consumption vulnerability in Mitsubish…7.5
- CVE-2021-20592Missing synchronization vulnerability in GOT2000 series GT27…7.5
- CVE-2021-20593Incorrect Implementation of Authentication Algorithm in Mits…7.1
Are you affected by CVE-2021-20588?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST