CVE-2021-32967
Last modified
CVE-2021-32967 is a critical-severity vulnerability rated 9.8/10 on the CVSS scale. Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to add a new administrative user without being authenticated or authorized, which may allow the attacker to log in and use the device with administrative privileges.. EPSS estimates a 1.38% chance of exploitation in the next 30 days.
Description
Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to add a new administrative user without being authenticated or authorized, which may allow the attacker to log in and use the device with administrative privileges.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Deltaww | Diaenergie | <= 1.7.5 |
References
- https://us-cert.cisa.gov/ics/advisories/icsa-21-238-03Third Party Advisory, US Government Resource
- https://us-cert.cisa.gov/ics/advisories/icsa-21-238-03Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2021-32967?
How severe is CVE-2021-32967?
How do I fix CVE-2021-32967?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2021
- CVE-2021-32961A getfile function in MDT AutoSave versions prior to v6.02.0…7.5
- CVE-2021-32962The AGG Software Web Server version 4.0.40.1014 and prior is…6.1
- CVE-2021-32963Null pointer dereference in SuiteLink server while processin…7.5
- CVE-2021-32964The AGG Software Web Server version 4.0.40.1014 and prior is…5.3
- CVE-2021-32965Delta Electronics DIAScreen versions prior to 1.1.0 are vuln…7.8
- CVE-2021-32966Philips Interoperability Solution XDS versions 2.5 through 3…7.5
- CVE-2021-32968Two buffer overflows in the built-in web server in Moxa NPor…7.5
- CVE-2021-32969Delta Electronics DIAScreen versions prior to 1.1.0 are vuln…7.8
- CVE-2021-3297On Zyxel NBG2105 V1.00(AAGU.2)C0 devices, setting the login …7.8
- CVE-2021-32970Data can be copied without validation in the built-in web se…7.5
- CVE-2021-32971Null pointer dereference in SuiteLink server while processin…7.5
- CVE-2021-32972Panasonic FPWIN Pro, all Versions 7.5.1.1 and prior, allows …5.5
Are you affected by CVE-2021-32967?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST