CVE-2021-33013
HIGHCVSS 7.5/10EPSS 0.76%
Last modified
CVE-2021-33013 is a high-severity vulnerability rated 7.5/10 on the CVSS scale. mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive system information.. EPSS estimates a 0.76% chance of exploitation in the next 30 days.
Description
mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive system information.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Myscada | Mypro | < 8.20.0 |
References
- https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03Third Party Advisory, US Government Resource
- https://www.myscada.org/version-8-20-0-released-security-updateRelease Notes, Vendor Advisory
- https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03Third Party Advisory, US Government Resource
- https://www.myscada.org/version-8-20-0-released-security-updateRelease Notes, Vendor Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2021-33013?
mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive system information.
How severe is CVE-2021-33013?
CVE-2021-33013 has a CVSS score of 7.5/10 (HIGH severity). The EPSS model estimates a 0.76% probability of exploitation in the next 30 days.
How do I fix CVE-2021-33013?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.
How Strix Helps
- Uncovering a hidden BOLA in Appsmith's snapshot logicStrix autonomously discovered a BOLA/IDOR vulnerability in Appsmith's snapshot deletion path.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2021
- CVE-2021-33007A heap-based buffer overflow in Delta Electronics TPEditor: …7.8
- CVE-2021-33008AVEVA System Platform versions 2017 through 2020 R2 P01 does…9.8
- CVE-2021-33009mySCADA myPRO versions prior to 8.20.0 allows an unauthentic…7.5
- CVE-2021-33010An exception is thrown from a function in AVEVA System Platf…7.5
- CVE-2021-33011All versions of the afffected TOYOPUC-PC10 Series,TOYOPUC-Pl…4.3
- CVE-2021-33012Rockwell Automation MicroLogix 1100, all versions, allows a …8.6
- CVE-2021-33014An attacker can gain VxWorks Shell after login due to hard-c…8.8
- CVE-2021-33015Cscape (All Versions prior to 9.90 SP5) lacks proper validat…7.8
- CVE-2021-33016An attacker can gain full access (read/write/delete) to sens…9.8
- CVE-2021-33017The standard access path of the IntelliBridge EC 40 and 60 H…8.8
- CVE-2021-33018The use of a broken or risky cryptographic algorithm in Phil…7.5
- CVE-2021-33019A stack-based buffer overflow vulnerability in Delta Electro…7.8
Are you affected by CVE-2021-33013?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST