CVE-2021-33722
Last modified
CVE-2021-33722 is a medium-severity vulnerability rated 4.9/10 on the CVSS scale. A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system has a Path Traversal vulnerability when exporting a firmware container. EPSS estimates a 0.83% chance of exploitation in the next 30 days.
Description
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system has a Path Traversal vulnerability when exporting a firmware container. With this a privileged authenticated attacker could create arbitrary files on an affected system.
Metrics
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Sinec Nms | < 1.0 |
| Siemens | Sinec Nms | 1.0 |
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdfPatch, Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdfPatch, Vendor Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2021-33722?
How severe is CVE-2021-33722?
How do I fix CVE-2021-33722?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2021
- CVE-2021-33716A vulnerability has been identified in SIMATIC CP 1543-1 (in…6.5
- CVE-2021-33717A vulnerability has been identified in JT2Go (All versions <…5.5
- CVE-2021-33718A vulnerability has been identified in Mendix Applications u…5.3
- CVE-2021-33719A vulnerability has been identified in SIPROTEC 5 relays wit…9.8
- CVE-2021-33720A vulnerability has been identified in SIPROTEC 5 relays wit…7.5
- CVE-2021-33721A vulnerability has been identified in SINEC NMS (All versio…7.2
- CVE-2021-33723A vulnerability has been identified in SINEC NMS (All versio…6.5
- CVE-2021-33724A vulnerability has been identified in SINEC NMS (All versio…9.1
- CVE-2021-33725A vulnerability has been identified in SINEC NMS (All versio…9.1
- CVE-2021-33726A vulnerability has been identified in SINEC NMS (All versio…7.5
- CVE-2021-33727A vulnerability has been identified in SINEC NMS (All versio…6.5
- CVE-2021-33728A vulnerability has been identified in SINEC NMS (All versio…7.2
Are you affected by CVE-2021-33722?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST