CVE-2021-38422
HIGHCVSS 7.8/10EPSS 0.17%
Last modified
CVE-2021-38422 is a high-severity vulnerability rated 7.8/10 on the CVSS scale. Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges.. EPSS estimates a 0.17% chance of exploitation in the next 30 days.
Description
Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges.
Metrics
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Deltaww | Dialink | <= 1.2.4.0 |
References
- https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02Third Party Advisory, US Government Resource
- https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2021-38422?
Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges.
How severe is CVE-2021-38422?
CVE-2021-38422 has a CVSS score of 7.8/10 (HIGH severity). The EPSS model estimates a 0.17% probability of exploitation in the next 30 days.
How do I fix CVE-2021-38422?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2021
- CVE-2021-38417VISAM VBASE version 11.6.0.6 is vulnerable to improper acces…7.5
- CVE-2021-38418Delta Electronics DIALink versions 1.2.4.0 and prior runs by…5.9
- CVE-2021-38419Fuji Electric V-Server Lite and Tellus Lite V-Simulator prio…7.8
- CVE-2021-3842nltk is vulnerable to Inefficient Regular Expression Complex…7.5
- CVE-2021-38420Delta Electronics DIALink versions 1.2.4.0 and prior default…7.8
- CVE-2021-38421Fuji Electric V-Server Lite and Tellus Lite V-Simulator prio…7.1
- CVE-2021-38423All versions of GurumDDS improperly calculate the size to be…9.8
- CVE-2021-38424The tag interface of Delta Electronics DIALink versions 1.2.…7.8
- CVE-2021-38425eProsima Fast DDS versions prior to 2.4.0 (#2269) are suscep…9.1
- CVE-2021-38426FATEK Automation WinProladder versions 3.30 and prior lacks …7.8
- CVE-2021-38427RTI Connext DDS Professional and Connext DDS Secure Versions…7.8
- CVE-2021-38428Delta Electronics DIALink versions 1.2.4.0 and prior is vuln…4.8
Are you affected by CVE-2021-38422?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST