Last modified

CVE-2022-1368 is a critical-severity vulnerability rated 9.8/10 on the CVSS scale. The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.. EPSS estimates a 0.78% chance of exploitation in the next 30 days.

Description

The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.

Metrics

CVSS 3.1
9.8/10

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

EPSS Probability
0.78%

51.2th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
Cognex3d-A1000 Dimensioning System Firmware<= 1.0.3\(3354\)

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2022-1368?
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
How severe is CVE-2022-1368?
CVE-2022-1368 has a CVSS score of 9.8/10 (CRITICAL severity). The EPSS model estimates a 0.78% probability of exploitation in the next 30 days.
How do I fix CVE-2022-1368?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2022-1368?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST