CVE-2022-24117
CRITICALCVSS 9.8/10EPSS 0.35%
Last modified
CVE-2022-24117 is a critical-severity vulnerability rated 9.8/10 on the CVSS scale. Certain General Electric Renewable Energy products download firmware without an integrity check. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.. EPSS estimates a 0.35% chance of exploitation in the next 30 days.
Description
Certain General Electric Renewable Energy products download firmware without an integrity check. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Ge | Inet 900 Firmware | < 8.3.0 |
| Ge | Inet Ii 900 Firmware | < 8.3.0 |
| Ge | Sd1 Firmware | <= 6.4.7 |
| Ge | Sd2 Firmware | < 6.4.7 |
| Ge | Sd4 Firmware | < 6.4.7 |
| Ge | Sd9 Firmware | < 6.4.7 |
| Ge | Td220max Firmware | < 1.2.6 |
| Ge | Td220x Firmware | < 2.0.16 |
References
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-06Patch, Third Party Advisory, US Government Resource
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-06Patch, Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2022-24117?
Certain General Electric Renewable Energy products download firmware without an integrity check. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.
How severe is CVE-2022-24117?
CVE-2022-24117 has a CVSS score of 9.8/10 (CRITICAL severity). The EPSS model estimates a 0.35% probability of exploitation in the next 30 days.
How do I fix CVE-2022-24117?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2022
- CVE-2022-24111In Mahara 21.04 before 21.04.3 and 21.10 before 21.10.1, por…5.3
- CVE-2022-24112An attacker can abuse the batch-requests plugin to send requ…9.8
- CVE-2022-24113Local privilege escalation due to excessive permissions assi…7.8
- CVE-2022-24114Local privilege escalation due to race condition on applicat…7
- CVE-2022-24115Local privilege escalation due to unrestricted loading of un…7.8
- CVE-2022-24116Certain General Electric Renewable Energy products have inad…9.8
- CVE-2022-24118Certain General Electric Renewable Energy products allow att…9.1
- CVE-2022-24119Certain General Electric Renewable Energy products have a hi…9.8
- CVE-2022-2412The Better Tag Cloud WordPress plugin through 0.99.5 does no…4.8
- CVE-2022-24120Certain General Electric Renewable Energy products store cle…4.6
- CVE-2022-24121SQL Injection vulnerability discovered in Unified Office Tot…7.5
- CVE-2022-24122kernel/ucount.c in the Linux kernel 5.14 through 5.16.4, whe…7.8
Are you affected by CVE-2022-24117?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST
