CVE-2022-28377

HIGHCVSS 7.5/10EPSS 0.81%

Last modified

CVE-2022-28377 is a high-severity vulnerability rated 7.5/10 on the CVSS scale. On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static account username/password for access control. This password can be generated via a binary included in the firmware, after ascertaining the MAC address of the IDU's base Ethernet interface, and adding the string DEVICE_MANUFACTURER='Wistron_NeWeb_Corp.' to /etc/device_info to replicate the host environment. EPSS estimates a 0.81% chance of exploitation in the next 30 days.

Description

On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static account username/password for access control. This password can be generated via a binary included in the firmware, after ascertaining the MAC address of the IDU's base Ethernet interface, and adding the string DEVICE_MANUFACTURER='Wistron_NeWeb_Corp.' to /etc/device_info to replicate the host environment. This occurs in /etc/init.d/wnc_factoryssidkeypwd (IDU).

Metrics

CVSS 3.1
7.5/10

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

EPSS Probability
0.81%

52.2th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
VerizonLvskihp Indoorunit Firmware3.4.66.162
VerizonLvskihp Outdoorunit Firmware3.33.101.0

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2022-28377?
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static account username/password for access control. This password can be generated via a binary included in the firmware, after ascertaining the MAC address of the IDU's base Ethernet interface, and adding the string DEVICE_MANUFACTURER='Wistron_NeWeb_Corp.' to /etc/device_info to replicate the host environment. This occurs in /etc/init.d/wnc_factoryssidkeypwd (IDU).
How severe is CVE-2022-28377?
CVE-2022-28377 has a CVSS score of 7.5/10 (HIGH severity). The EPSS model estimates a 0.81% probability of exploitation in the next 30 days.
How do I fix CVE-2022-28377?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2022-28377?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST