CVE-2022-33139

CRITICALCVSS 9.8/10EPSS 1.17%

Last modified

CVE-2022-33139 is a critical-severity vulnerability rated 9.8/10 on the CVSS scale. A vulnerability has been identified in Cerberus DMS (All versions), Desigo CC (All versions), Desigo CC Compact (All versions), SIMATIC WinCC OA V3.16 (All versions in default configuration), SIMATIC WinCC OA V3.17 (All versions in non-default configuration), SIMATIC WinCC OA V3.18 (All versions in non-default configuration). Affected applications use client-side only authentication, when neither server-side authentication (SSA) nor Kerberos authentication is enabled. EPSS estimates a 1.17% chance of exploitation in the next 30 days.

Description

A vulnerability has been identified in Cerberus DMS (All versions), Desigo CC (All versions), Desigo CC Compact (All versions), SIMATIC WinCC OA V3.16 (All versions in default configuration), SIMATIC WinCC OA V3.17 (All versions in non-default configuration), SIMATIC WinCC OA V3.18 (All versions in non-default configuration). Affected applications use client-side only authentication, when neither server-side authentication (SSA) nor Kerberos authentication is enabled. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated.

Metrics

CVSS 3.1
9.8/10

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

EPSS Probability
1.17%

63.3th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
SiemensCerberus DmsAll versions
SiemensDesigo CcAll versions
SiemensDesigo Cc CompactAll versions
SiemensWincc Open Architecture3.16
SiemensWincc Open Architecture3.17
SiemensWincc Open Architecture3.18

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2022-33139?
A vulnerability has been identified in Cerberus DMS (All versions), Desigo CC (All versions), Desigo CC Compact (All versions), SIMATIC WinCC OA V3.16 (All versions in default configuration), SIMATIC WinCC OA V3.17 (All versions in non-default configuration), SIMATIC WinCC OA V3.18 (All versions in non-default configuration). Affected applications use client-side only authentication, when neither server-side authentication (SSA) nor Kerberos authentication is enabled. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated.
How severe is CVE-2022-33139?
CVE-2022-33139 has a CVSS score of 9.8/10 (CRITICAL severity). The EPSS model estimates a 1.17% probability of exploitation in the next 30 days.
How do I fix CVE-2022-33139?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2022-33139?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now