CVE-2022-40202
Last modified
CVE-2022-40202 is a critical-severity vulnerability rated 9.8/10 on the CVSS scale. The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. EPSS estimates a 1.24% chance of exploitation in the next 30 days.
Description
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Deltaww | Infrasuite Device Master | < 00.00.02a |
References
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07Patch, Third Party Advisory, US Government Resource
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07Patch, Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2022-40202?
How severe is CVE-2022-40202?
How do I fix CVE-2022-40202?
Are you affected by CVE-2022-40202?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST