CVE-2022-41778
Last modified
CVE-2022-41778 is a high-severity vulnerability rated 8.8/10 on the CVSS scale. Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization. EPSS estimates a 1.03% chance of exploitation in the next 30 days.
Description
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
Metrics
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Deltaww | Infrasuite Device Master | <= 00.00.01a |
References
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07Third Party Advisory, US Government Resource
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2022-41778?
How severe is CVE-2022-41778?
How do I fix CVE-2022-41778?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2022
- CVE-2022-41771Incorrect permission assignment for critical resource in som…5.5
- CVE-2022-41772 Delta Electronics InfraSuite Device Master Versions 00.00.0…9.8
- CVE-2022-41773The affected product DIAEnergie (versions prior to v1.9.01.0…8.8
- CVE-2022-41775SQL Injection in Handler_CFG.ashx in Delta Electroni…8.8
- CVE-2022-41776 Delta Electronics InfraSuite Device Master versions 00.00.0…7.5
- CVE-2022-41777Improper check or handling of exceptional conditions vulnera…7.5
- CVE-2022-41779 Delta Electronics InfraSuite Device Master versions 00.00.0…9.8
- CVE-2022-4178Use after free in Mojo in Google Chrome prior to 108.0.5359.…8.8
- CVE-2022-41780In F5OS-A version 1.x before 1.1.0 and F5OS-C version 1.x be…5.5
- CVE-2022-41781Broken Access Control vulnerability in Permalink Manager Lit…9.8
- CVE-2022-41782Rejected reason: This CVE ID has been rejected or withdrawn …
- CVE-2022-41783tdpServer of TP-Link RE300 V1 improperly processes its input…5.5
Are you affected by CVE-2022-41778?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST