CVE-2023-23579
Last modified
CVE-2023-23579 is a high-severity vulnerability rated 7.8/10 on the CVSS scale. Datakit CrossCadWare_x64.dll contains an out-of-bounds write past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This could allow an attacker to execute code in the context of the current process. EPSS estimates a 0.24% chance of exploitation in the next 30 days.
Description
Datakit CrossCadWare_x64.dll contains an out-of-bounds write past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This could allow an attacker to execute code in the context of the current process.
Metrics
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Datakit | Crosscadware | < 2023.1 |
References
- https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-14Mitigation, Third Party Advisory, US Government Resource
- https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-14Mitigation, Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2023-23579?
How severe is CVE-2023-23579?
How do I fix CVE-2023-23579?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2023
- CVE-2023-23573Improper access control in the Intel(R) Unite(R) android app…4.4
- CVE-2023-23574A blind SQL Injection vulnerability in Nozomi Networks Guard…8.8
- CVE-2023-23575Improper access control vulnerability in CONPROSYS IoT Gatew…4.3
- CVE-2023-23576 Incorrect behavior order in the Command Centre Server could…4.3
- CVE-2023-23577Uncontrolled search path element for some ITE Tech consumer …7.3
- CVE-2023-23578Improper access control vulnerability in SkyBridge MB-A200 f…7.5
- CVE-2023-2358 Hitachi Vantara Pentaho Business Analytics Server prior to …4.9
- CVE-2023-23580Stack-based buffer overflow for some Intel(R) Trace Analyzer…7.8
- CVE-2023-23581A denial-of-service vulnerability exists in the vpnserver En…7.5
- CVE-2023-23582 Snap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior a…9.8
- CVE-2023-23583Sequence of processor instructions leads to unexpected behav…7.8
- CVE-2023-23584 An observable response discrepancy in the Gallagher Command…4.3
Are you affected by CVE-2023-23579?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST
