CVE-2023-25931
Last modified
CVE-2023-25931 is a medium-severity vulnerability rated 6.8/10 on the CVSS scale. Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix. Not updating could potentially result in unauthorized control of the clinician therapy application, which has greater control over therapy parameters than the patient app. EPSS estimates a 0.27% chance of exploitation in the next 30 days.
Description
Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix. Not updating could potentially result in unauthorized control of the clinician therapy application, which has greater control over therapy parameters than the patient app. Changes still cannot be made outside of the established therapy parameters of the programmer. For unauthorized access to occur, an individual would need physical access to the Smart Programmer.
Metrics
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Medtronic | Interstim X Clinician | a51300 |
| Medtronic | Micro Clinician | a51200 |
References
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2023-25931?
How severe is CVE-2023-25931?
How do I fix CVE-2023-25931?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2023
- CVE-2023-25926IBM Security Guardium Key Lifecycle Manager 3.0, 3.0.1, 4.0,…8.2
- CVE-2023-25927IBM Security Verify Access 10.0.0, 10.0.1, 10.0.2, 10.0.3, 1…7.5
- CVE-2023-25928IBM InfoSphere Information Server 11.7 is vulnerable to cros…5.4
- CVE-2023-25929IBM Cognos Analytics 11.1 and 11.2 is vulnerable to cross-si…5.4
- CVE-2023-2593A flaw exists within the Linux kernel's handling of new TCP …5.9
- CVE-2023-25930IBM Db2 for Linux, UNIX and Windows (includes Db2 Connect Se…5.9
- CVE-2023-25933A type confusion bug in TypedArray prior to commit e6ed9c1a4…9.8
- CVE-2023-25934 DELL ECS prior to 3.8.0.2 contains an improper verification…7.5
- CVE-2023-25936 Dell BIOS contains an improper input validation vulnerabili…6.7
- CVE-2023-25937 Dell BIOS contains an improper input validation vulnerabili…6.7
- CVE-2023-25938 Dell BIOS contains an improper input validation vulnerabili…6.7
- CVE-2023-2594A vulnerability, which was classified as critical, was found…9.8
Are you affected by CVE-2023-25931?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST