CVE-2023-28831
Last modified
CVE-2023-28831 is a high-severity vulnerability rated 8.7/10 on the CVSS scale. The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.. EPSS estimates a 0.82% chance of exploitation in the next 30 days.
Description
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Simatic Cloud Connect 7 Cc712 Firmware | < 2.2 |
| Siemens | Simatic Cloud Connect 7 Cc716 Firmware | < 2.2 |
| Siemens | Simatic Drive Controller Cpu 1504d Tf Firmware | < 2.2 |
| Siemens | Simatic Drive Controller Cpu 1507d Tf Firmware | < 2.9.7 |
| Siemens | Simatic Et 200sp Open Controller Cpu Firmware | < 2.9.7 |
| Siemens | Simatic S7-1200 Cpu Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1510sp-1 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1510sp F-1 Pn Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1511-1 Pn Firmware | < 21.9.7 |
| Siemens | Simatic S7-1500 Cpu 1511c-1 Pn Firmware | < 30.0.0 |
| Siemens | Simatic S7-1500 Cpu 1511f-1 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1511t-1 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1511tf-1 Pn Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1512c-1 Pn Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1512sp-1 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1512sp F-1 Pn Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1513-1 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1513f-1 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1513r-1 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1514sp-2 Pn Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1514sp F-2 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1514spt-2 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1514spt F-2 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1515-2 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1515f-2 Pn Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1515r-2 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1515t-2 Pn Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1515tf-2 Pn Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1516-3 Pn\/Dp Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1516f-3 Pn\/Dp Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1516t-3 Pn\/Dp Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1516tf-3 Pn\/Dp Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1517-3 Pn\/Dp Firmware | < 3.0.3 |
| Siemens | Simatic S7-1500 Cpu 1517f-3 Pn\/Dp Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1517h-3 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1517t-3 Pn\/Dp Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1517tf-3 Pn\/Dp Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1518-4 Pn\/Dp Firmware | < 21.9.7 |
| Siemens | Simatic S7-1500 Cpu 1518-4 Pn\/Dp Mfp Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1518f-4 Pn\/Dp Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1518f-4 Pn\/Dp Mfp Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1518hf-4 Pn Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1518t-4 Pn\/Dp Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu 1518tf-4 Pn\/Dp Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu S7-1518-4 Pn\/Dp Odk Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Cpu S7-1518f-4 Pn\/Dp Odk Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Et 200pro Firmware | < 2.9.7 |
| Siemens | Simatic S7-1500 Software Controller Firmware | < 2.9.7 |
| Siemens | Simatic S7-Plcsim Advanced Firmware | < 2.9.7 |
| Siemens | Siplus Et 200sp Cpu 1510sp-1 Pn Firmware | < 2.9.7 |
Showing 50 of 78 affected configurations. See NVD for the full list.
References
- https://cert-portal.siemens.com/productcert/html/ssa-118850.htmlMitigation, Vendor Advisory
- https://cert-portal.siemens.com/productcert/html/ssa-711309.htmlMitigation, Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdfMitigation, Vendor Advisory
- https://cert-portal.siemens.com/productcert/html/ssa-118850.htmlMitigation, Vendor Advisory
- https://cert-portal.siemens.com/productcert/html/ssa-711309.htmlMitigation, Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdfMitigation, Vendor Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2023-28831?
How severe is CVE-2023-28831?
How do I fix CVE-2023-28831?
Are you affected by CVE-2023-28831?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST