CVE-2023-2914
Last modified
CVE-2023-2914 is a high-severity vulnerability rated 7.5/10 on the CVSS scale. The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, an integer overflow condition exists in the affected products. When the ThinManager processes incoming messages, a read access violation occurs and terminates the process. EPSS estimates a 27.01% chance of exploitation in the next 30 days.
Description
The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, an integer overflow condition exists in the affected products. When the ThinManager processes incoming messages, a read access violation occurs and terminates the process. A malicious user could exploit this vulnerability by sending a crafted synchronization protocol message and causing a denial of service condition in the software.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Rockwellautomation | Thinmanager Thinserver | >= 11.0.0, <= 11.0.6 |
| Rockwellautomation | Thinmanager Thinserver | >= 11.1.0, <= 11.1.6 |
| Rockwellautomation | Thinmanager Thinserver | >= 11.2.0, <= 11.2.7 |
| Rockwellautomation | Thinmanager Thinserver | >= 12.0.0, <= 12.0.5 |
| Rockwellautomation | Thinmanager Thinserver | >= 12.1.0, <= 12.1.6 |
| Rockwellautomation | Thinmanager Thinserver | >= 13.0.0, <= 13.0.2 |
| Rockwellautomation | Thinmanager Thinserver | 13.1.0 |
References
- https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140471Permissions Required
- https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140471Permissions Required
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2023-2914?
How severe is CVE-2023-2914?
How do I fix CVE-2023-2914?
Are you affected by CVE-2023-2914?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST