CVE-2023-32201
Last modified
CVE-2023-32201 is a high-severity vulnerability rated 7.8/10 on the CVSS scale. Stack-based buffer overflow vulnerability exists in TELLUS v4.0.15.0 and TELLUS Lite v4.0.15.0. Opening a specially crafted SIM2 file may lead to information disclosure and/or arbitrary code execution. EPSS estimates a 0.28% chance of exploitation in the next 30 days.
Description
Stack-based buffer overflow vulnerability exists in TELLUS v4.0.15.0 and TELLUS Lite v4.0.15.0. Opening a specially crafted SIM2 file may lead to information disclosure and/or arbitrary code execution. This vulnerability is different from CVE-2023-32538 and CVE-2023-32273.
Metrics
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Fujielectric | Tellus | 4.0.15.0 |
| Fujielectric | Tellus Lite | 4.0.15.0 |
References
- https://jvn.jp/en/vu/JVNVU98818508/Third Party Advisory
- https://jvn.jp/en/vu/JVNVU98818508/Third Party Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2023-32201?
How severe is CVE-2023-32201?
How do I fix CVE-2023-32201?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2023
- CVE-2023-32194A vulnerability has been identified when granting a create o…8.6
- CVE-2023-32196A vulnerability has been identified whereby privilege escala…7.5
- CVE-2023-32197A Improper Privilege Management vulnerability in SUSE ranche…7.5
- CVE-2023-32199A vulnerability has been identified within Rancher Manager,…4.3
- CVE-2023-3220An issue was discovered in the Linux kernel through 6.1-rc8.…5.5
- CVE-2023-32200There is insufficient restrictions of called script function…8.8
- CVE-2023-32202Walchem Intuition 9 firmware versions prior to v4.21 are vul…8.8
- CVE-2023-32203Horner Automation Cscape lacks proper validation of user-sup…7.8
- CVE-2023-32204Improper access control in some Intel(R) OFU software before…7.8
- CVE-2023-32205In multiple cases browser prompts could have been obscured b…4.3
- CVE-2023-32206An out-of-bound read could have led to a crash in the RLBox …6.5
- CVE-2023-32207A missing delay in popup notifications could have made it po…8.8
Are you affected by CVE-2023-32201?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST