CVE-2023-46141
CRITICALCVSS 9.8/10EPSS 0.88%
Last modified
CVE-2023-46141 is a critical-severity vulnerability rated 9.8/10 on the CVSS scale. Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device.. EPSS estimates a 0.88% chance of exploitation in the next 30 days.
Description
Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Phoenixcontact | Automationworx Software Suite | All versions |
| Phoenixcontact | Axc 1050 Firmware | All versions |
| Phoenixcontact | Axc 1050 Xc Firmware | All versions |
| Phoenixcontact | Axc 3050 Firmware | All versions |
| Phoenixcontact | Config\+ | All versions |
| Phoenixcontact | Fc 350 Pci Eth Firmware | All versions |
| Phoenixcontact | Ilc1x0 Firmware | All versions |
| Phoenixcontact | Ilc1x1 Firmware | All versions |
| Phoenixcontact | Ilc 3xx Firmware | All versions |
| Phoenixcontact | Pc Worx | All versions |
| Phoenixcontact | Pc Worx Express | All versions |
| Phoenixcontact | Pc Worx Rt Basic Firmware | All versions |
| Phoenixcontact | Pc Worx Srt | All versions |
| Phoenixcontact | Rfc 430 Eth-Ib Firmware | All versions |
| Phoenixcontact | Rfc 450 Eth-Ib Firmware | All versions |
| Phoenixcontact | Rfc 460r Pn 3tx Firmware | All versions |
| Phoenixcontact | Rfc 470s Pn 3tx Firmware | All versions |
| Phoenixcontact | Rfc 480s Pn 4tx Firmware | All versions |
References
- https://cert.vde.com/en/advisories/VDE-2023-055/Third Party Advisory
- https://cert.vde.com/en/advisories/VDE-2023-055/Third Party Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2023-46141?
Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device.
How severe is CVE-2023-46141?
CVE-2023-46141 has a CVSS score of 9.8/10 (CRITICAL severity). The EPSS model estimates a 0.88% probability of exploitation in the next 30 days.
How do I fix CVE-2023-46141?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.
Are you affected by CVE-2023-46141?
Run a free Strix scan to check your systems for this vulnerability.