CVE-2023-46285
Last modified
CVE-2023-46285 is a high-severity vulnerability rated 7.5/10 on the CVSS scale. A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. EPSS estimates a 0.91% chance of exploitation in the next 30 days.
Description
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Opcenter Quality | All versions |
| Siemens | Simatic Pcs Neo | < 4.1 |
| Siemens | Sinumerik Integrate Runmyhmi \/Automotive | All versions |
| Siemens | Totally Integrated Automation Portal | >= 14.0, < 15 |
| Siemens | Totally Integrated Automation Portal | >= 15, < 16 |
| Siemens | Totally Integrated Automation Portal | >= 16, < 17 |
| Siemens | Totally Integrated Automation Portal | >= 17, < 18 |
| Siemens | Totally Integrated Automation Portal | All versions |
| Siemens | Totally Integrated Automation Portal | 18 |
References
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2023-46285?
How severe is CVE-2023-46285?
How do I fix CVE-2023-46285?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2023
- CVE-2023-4628The LadiApp plugin for WordPress is vulnerable to Cross-Site…4.3
- CVE-2023-46280A vulnerability has been identified in Security Configuratio…8.2
- CVE-2023-46281A vulnerability has been identified in Opcenter Execution Fo…8.8
- CVE-2023-46282A vulnerability has been identified in Opcenter Execution Fo…6.1
- CVE-2023-46283A vulnerability has been identified in Opcenter Execution Fo…7.5
- CVE-2023-46284A vulnerability has been identified in Opcenter Execution Fo…7.5
- CVE-2023-46287XSS exists in NagVis before 1.9.38 via the select function i…6.1
- CVE-2023-46288Exposure of Sensitive Information to an Unauthorized Actor v…4.3
- CVE-2023-46289 Rockwell Automation FactoryTalk View Site Edition insuffici…7.5
- CVE-2023-4629The LadiApp plugin for WordPress is vulnerable to Cross-Site…4.3
- CVE-2023-46290 Due to inadequate code logic, a previously unauthenticated …8.1
- CVE-2023-46294An issue was discovered in Teledyne FLIR M300 2.00-19. User …3.4
Are you affected by CVE-2023-46285?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST