CVE-2023-4667
Last modified
CVE-2023-4667 is a medium-severity vulnerability rated 4.8/10 on the CVSS scale. The web interface of the PAC Device allows the device administrator user profile to store malicious scripts in some fields. The stored malicious script is then executed when the GUI is opened by any users of the webserver administration interface. The root cause of the vulnerability is inadequate input validation and output encoding in the web administration interface component of the firmware. This could lead to unauthorized access and data leakage . EPSS estimates a 0.42% chance of exploitation in the next 30 days.
Description
The web interface of the PAC Device allows the device administrator user profile to store malicious scripts in some fields. The stored malicious script is then executed when the GUI is opened by any users of the webserver administration interface. The root cause of the vulnerability is inadequate input validation and output encoding in the web administration interface component of the firmware. This could lead to unauthorized access and data leakage
Metrics
CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Idemia | Sgima Lite \& Lite\+ Firmware | All versions |
| Idemia | Sigma Wide Firmware | All versions |
| Idemia | Sigma Extreme Firmware | All versions |
| Idemia | Morphowave Compact Firmware | All versions |
| Idemia | Morphowave Sp Firmware | All versions |
| Idemia | Visionpass Firmware | All versions |
References
- https://www.idemia.com/vulnerability-informationVendor Advisory
- https://www.idemia.com/vulnerability-informationVendor Advisory