CVE-2024-20342

HIGHCVSS 8.6/10EPSS 0.51%

Last modified

CVE-2024-20342 is a high-severity vulnerability rated 8.6/10 on the CVSS scale. Multiple Cisco products are affected by a vulnerability in the rate filtering feature of the Snort detection engine that could allow an unauthenticated, remote attacker to bypass a configured rate limiting filter.  This vulnerability is due to an incorrect connection count comparison. An attacker could exploit this vulnerability by sending traffic through an affected device at a rate that exceeds a configured rate filter. EPSS estimates a 0.51% chance of exploitation in the next 30 days.

Description

Multiple Cisco products are affected by a vulnerability in the rate filtering feature of the Snort detection engine that could allow an unauthenticated, remote attacker to bypass a configured rate limiting filter.  This vulnerability is due to an incorrect connection count comparison. An attacker could exploit this vulnerability by sending traffic through an affected device at a rate that exceeds a configured rate filter. A successful exploit could allow the attacker to successfully bypass the rate filter. This could allow unintended traffic to enter the network protected by the affected device.

Metrics

CVSS 3.1
8.6/10

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N

EPSS Probability
0.51%

39.6th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
CiscoSnort>= 3.0.0.0, < 3.1.74.0
CiscoFirepower Threat Defense Software< 7.0.6.2
CiscoFirepower Threat Defense Software>= 7.2.0, < 7.2.6
CiscoFirepower Threat Defense Software>= 7.4.0, < 7.4.2
CiscoFirepower Threat Defense Software7.1.0
CiscoFirepower Threat Defense Software7.3.0

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2024-20342?
Multiple Cisco products are affected by a vulnerability in the rate filtering feature of the Snort detection engine that could allow an unauthenticated, remote attacker to bypass a configured rate limiting filter.&nbsp; This vulnerability is due to an incorrect connection count comparison. An attacker could exploit this vulnerability by sending traffic through an affected device at a rate that exceeds a configured rate filter. A successful exploit could allow the attacker to successfully bypass the rate filter. This could allow unintended traffic to enter the network protected by the affected device.
How severe is CVE-2024-20342?
CVE-2024-20342 has a CVSS score of 8.6/10 (HIGH severity). The EPSS model estimates a 0.51% probability of exploitation in the next 30 days.
How do I fix CVE-2024-20342?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2024-20342?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST