CVE-2024-23620
HIGHCVSS 7.8/10EPSS 0.16%
Last modified
CVE-2024-23620 is a high-severity vulnerability rated 7.8/10 on the CVSS scale. An improper privilege management vulnerability exists in IBM Merge Healthcare eFilm Workstation. A local, authenticated attacker can exploit this vulnerability to escalate privileges to SYSTEM. . EPSS estimates a 0.16% chance of exploitation in the next 30 days.
Description
An improper privilege management vulnerability exists in IBM Merge Healthcare eFilm Workstation. A local, authenticated attacker can exploit this vulnerability to escalate privileges to SYSTEM.
Metrics
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Ibm | Merge Efilm Workstation | <= 4.2 |
References
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2024-23620?
An improper privilege management vulnerability exists in IBM Merge Healthcare eFilm Workstation. A local, authenticated attacker can exploit this vulnerability to escalate privileges to SYSTEM.
How severe is CVE-2024-23620?
CVE-2024-23620 has a CVSS score of 7.8/10 (HIGH severity). The EPSS model estimates a 0.16% probability of exploitation in the next 30 days.
How do I fix CVE-2024-23620?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2024
- CVE-2024-23615A buffer overflow vulnerability exists in Symantec Messaging…9.8
- CVE-2024-23616A buffer overflow vulnerability exists in Symantec Server Ma…9.8
- CVE-2024-23617A buffer overflow vulnerability exists in Symantec Data Loss…8.8
- CVE-2024-23618An arbitrary code execution vulnerability exists in Arris SU…9.8
- CVE-2024-23619A hardcoded credential vulnerability exists in IBM Merge Hea…9.8
- CVE-2024-2362A path traversal vulnerability exists in the parisneo/lollms…9.1
- CVE-2024-23621A buffer overflow exists in IBM Merge Healthcare eFilm Works…9.8
- CVE-2024-23622A stack-based buffer overflow exists in IBM Merge Healthcare…9.8
- CVE-2024-23624A command injection vulnerability exists in the gena.cgi mod…9.8
- CVE-2024-23625A command injection vulnerability exists in D-Link DAP-1650 …9.8
- CVE-2024-23626A command injection vulnerability exists in the ‘SaveSysLogP…8.8
- CVE-2024-23627A command injection vulnerability exists in the 'SaveStaticR…8.8
Are you affected by CVE-2024-23620?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST