CVE-2024-3699 is a critical-severity vulnerability rated 9.8/10 on the CVSS scale. Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all drEryk Gabinet installations.This issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0.. EPSS estimates a 0.41% chance of exploitation in the next 30 days.
Description
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all drEryk Gabinet installations.This issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:C/RE:M/U:Red
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Dreryk | Gabinet | >= 7.0.0.0, < 9.17.0.0 |
References
- https://cert.pl/en/posts/2024/06/CVE-2024-1228/Third Party Advisory
- https://cert.pl/posts/2024/06/CVE-2024-1228/Third Party Advisory
- https://cert.pl/en/posts/2024/06/CVE-2024-1228/Third Party Advisory
- https://cert.pl/posts/2024/06/CVE-2024-1228/Third Party Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2024-3699?
How severe is CVE-2024-3699?
How do I fix CVE-2024-3699?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2024
- CVE-2024-36984In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10…8.8
- CVE-2024-36985In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10…8.8
- CVE-2024-36986In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10…5.7
- CVE-2024-36987In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10…6.5
- CVE-2024-36988Rejected reason: ** REJECT ** DO NOT USE THIS CANDIDATE NUMB…
- CVE-2024-36989In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10…4.3
- CVE-2024-36990In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10…6.5
- CVE-2024-36991In Splunk Enterprise on Windows versions below 9.2.2, 9.1.5,…7.5
- CVE-2024-36992In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10…5.4
- CVE-2024-36993In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10…5.4
- CVE-2024-36994In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10…5.4
- CVE-2024-36995In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10…3.5
Are you affected by CVE-2024-3699?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST