CVE-2024-37999
HIGHCVSS 7.8/10EPSS 0.14%
Last modified
CVE-2024-37999 is a high-severity vulnerability rated 7.8/10 on the CVSS scale. A vulnerability has been identified in Medicalis Workflow Orchestrator (All versions). The affected application executes as a trusted account with high privileges and network access. EPSS estimates a 0.14% chance of exploitation in the next 30 days.
Description
A vulnerability has been identified in Medicalis Workflow Orchestrator (All versions). The affected application executes as a trusted account with high privileges and network access. This could allow an authenticated local attacker to escalate privileges.
Metrics
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Medicalis Workflow Orchestrator | All versions |
References
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2024-37999?
A vulnerability has been identified in Medicalis Workflow Orchestrator (All versions). The affected application executes as a trusted account with high privileges and network access. This could allow an authenticated local attacker to escalate privileges.
How severe is CVE-2024-37999?
CVE-2024-37999 has a CVSS score of 7.8/10 (HIGH severity). The EPSS model estimates a 0.14% probability of exploitation in the next 30 days.
How do I fix CVE-2024-37999?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2024
- CVE-2024-37993A vulnerability has been identified in SIMATIC Reader RF610R…7.5
- CVE-2024-37994A vulnerability has been identified in SIMATIC Reader RF610R…7.1
- CVE-2024-37995A vulnerability has been identified in SIMATIC Reader RF610R…9.1
- CVE-2024-37996A vulnerability has been identified in JT Open (All versions…4.8
- CVE-2024-37997A vulnerability has been identified in JT Open (All versions…7.8
- CVE-2024-37998A vulnerability has been identified in CPCI85 Central Proces…9.8
- CVE-2024-3800Sites managed in S@M CMS (Concept Intermedia) might be vulne…6.1
- CVE-2024-38002The workflow component in Liferay Portal 7.3.2 through 7.4.3…8.8
- CVE-2024-3801Sites managed in S@M CMS (Concept Intermedia) might be vulne…6.1
- CVE-2024-38010Secure Boot Security Feature Bypass Vulnerability8
- CVE-2024-38011Secure Boot Security Feature Bypass Vulnerability8
- CVE-2024-38013Microsoft Windows Server Backup Elevation of Privilege Vulne…6.7
Are you affected by CVE-2024-37999?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST