CVE-2024-39570
Last modified
CVE-2024-39570 is a high-severity vulnerability rated 8.8/10 on the CVSS scale. A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading VxLAN configurations. EPSS estimates a 1.35% chance of exploitation in the next 30 days.
Description
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading VxLAN configurations. This could allow an authenticated attacker to execute arbitrary code with root privileges.
Metrics
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Sinema Remote Connect Server | < 3.2 |
| Siemens | Sinema Remote Connect Server | 3.2 |
References
- https://cert-portal.siemens.com/productcert/html/ssa-928781.htmlPatch, Vendor Advisory
- https://cert-portal.siemens.com/productcert/html/ssa-928781.htmlPatch, Vendor Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2024-39570?
How severe is CVE-2024-39570?
How do I fix CVE-2024-39570?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2024
- CVE-2024-39564This is a similar, but different vulnerability than the issu…8.7
- CVE-2024-39565An Improper Neutralization of Data within XPath Expressions …8.8
- CVE-2024-39567A vulnerability has been identified in SINEMA Remote Connect…8.5
- CVE-2024-39568A vulnerability has been identified in SINEMA Remote Connect…7.8
- CVE-2024-39569A vulnerability has been identified in SINEMA Remote Connect…7.2
- CVE-2024-3957The Booster for WooCommerce plugin is vulnerable to Unauthen…7.3
- CVE-2024-39571A vulnerability has been identified in SINEMA Remote Connect…8.8
- CVE-2024-39573Potential SSRF in mod_rewrite in Apache HTTP Server 2.4.59 a…7.5
- CVE-2024-39574Dell PowerScale InsightIQ, version 5.1, contain an Improper …4.4
- CVE-2024-39575update_disk_psu_baseline.sh requires password in plain text7.4
- CVE-2024-39576Dell Power Manager (DPM), versions 3.15.0 and prior, contain…8.8
- CVE-2024-39577Dell SmartFabric OS10 Software, versions 10.5.6.x, 10.5.5.x,…8.8
Are you affected by CVE-2024-39570?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST
