CVE-2024-7587 is a high-severity vulnerability rated 7.8/10 on the CVSS scale. Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32.. EPSS estimates a 0.19% chance of exploitation in the next 30 days.

Description

Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32.

Metrics

CVSS 3.1
7.8/10

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

EPSS Probability
0.19%

9.2th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
IconicsGenesis64<= 10.97.3
MitsubishielectricMc Works64All versions

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2024-7587?
Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32.
How severe is CVE-2024-7587?
CVE-2024-7587 has a CVSS score of 7.8/10 (HIGH severity). The EPSS model estimates a 0.19% probability of exploitation in the next 30 days.
How do I fix CVE-2024-7587?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.