CVE-2024-8956

CRITICALCVSS 9.1/10Actively ExploitedEPSS 60.88%

Last modified

CVE-2024-8956 is a critical-severity vulnerability rated 9.1/10 on the CVSS scale. PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. CISA has confirmed active exploitation in the wild. EPSS estimates a 60.88% chance of exploitation in the next 30 days.

Description

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.

Metrics

CVSS 3.1
9.1/10

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

EPSS Probability
60.88%

99.0th percentile

Probability of exploitation in the next 30 days. Learn more

Exploitation Status

This vulnerability is listed in CISA’s Known Exploited Vulnerabilities catalog, confirming active exploitation in the wild. Federal agencies must remediate by .

Weakness Enumeration

Affected Software

VendorProductVersions
PtzopticsPt30x-Sdi Firmware< 6.3.40
PtzopticsPt30x-Ndi-Xx-G2 Firmware< 6.3.40

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2024-8956?
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.
How severe is CVE-2024-8956?
CVE-2024-8956 has a CVSS score of 9.1/10 (CRITICAL severity). The EPSS model estimates a 60.88% probability of exploitation in the next 30 days. This vulnerability is listed in CISA's Known Exploited Vulnerabilities catalog.
How do I fix CVE-2024-8956?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2024-8956?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST