CVE-2025-21840
Last modified
CVE-2025-21840 is a medium-severity vulnerability rated 5.5/10 on the CVSS scale. In the Linux kernel, the following vulnerability has been resolved: thermal/netlink: Prevent userspace segmentation fault by adjusting UAPI header The intel-lpmd tool [1], which uses the THERMAL_GENL_ATTR_CPU_CAPABILITY attribute to receive HFI events from kernel space, encounters a segmentation fault after commit 1773572863c4 ("thermal: netlink: Add the commands and the events for the thresholds"). The issue arises because the THERMAL_GENL_ATTR_CPU_CAPABILITY raw value was changed while intel_lpmd still uses the old value. Although intel_lpmd can be updated to check the THERMAL_GENL_VERSION and use the appropriate THERMAL_GENL_ATTR_CPU_CAPABILITY value, the commit itself is questionable. The commit introduced a new element in the middle of enum thermal_genl_attr, which affects many existing attributes and introduces potential risks and unnecessary maintenance burdens for userspace thermal netlink event users. Solve the issue by moving the newly introduced THERMAL_GENL_ATTR_TZ_PREV_TEMP attribute to the end of the enum thermal_genl_attr. This ensures that all existing thermal generic netlink attributes remain unaffected. [ rjw: Subject edits ]. EPSS estimates a 0.19% chance of exploitation in the next 30 days.
Description
In the Linux kernel, the following vulnerability has been resolved: thermal/netlink: Prevent userspace segmentation fault by adjusting UAPI header The intel-lpmd tool [1], which uses the THERMAL_GENL_ATTR_CPU_CAPABILITY attribute to receive HFI events from kernel space, encounters a segmentation fault after commit 1773572863c4 ("thermal: netlink: Add the commands and the events for the thresholds"). The issue arises because the THERMAL_GENL_ATTR_CPU_CAPABILITY raw value was changed while intel_lpmd still uses the old value. Although intel_lpmd can be updated to check the THERMAL_GENL_VERSION and use the appropriate THERMAL_GENL_ATTR_CPU_CAPABILITY value, the commit itself is questionable. The commit introduced a new element in the middle of enum thermal_genl_attr, which affects many existing attributes and introduces potential risks and unnecessary maintenance burdens for userspace thermal netlink event users. Solve the issue by moving the newly introduced THERMAL_GENL_ATTR_TZ_PREV_TEMP attribute to the end of the enum thermal_genl_attr. This ensures that all existing thermal generic netlink attributes remain unaffected. [ rjw: Subject edits ]
Metrics
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Affected Software
| Vendor | Product | Versions | Update |
|---|---|---|---|
| Linux | Linux Kernel | >= 6.13, < 6.13.4 | — |
| Linux | Linux Kernel | 6.14 | Rc1 |
References
Timeline
- Published
- Last Modified
- Status
- Analyzed
Frequently Asked Questions
What is CVE-2025-21840?
How severe is CVE-2025-21840?
How do I fix CVE-2025-21840?
Are you affected by CVE-2025-21840?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST